Mayo Clinic Laboratories

Test Code ESTD Estradiol, Serum

Specimen Collection Requirements

Estradiol, 17-Beta, (E2), Serum

Alternate Test Name: EE2
Dept: Chemistry
SPECIMEN COLLECTION REQUIREMENTS
Collection Container:

SST

Specimen: Serum
Transport Temperature: Room Temperature
Specimen Volume: Preferred Volume: 1 mL; Minimum Volume: 0.5 mL
Also Acceptable: Red Top Tube
TECHNICAL SPECIFICATIONS
Performed: Monday - Saturday
Reported: Same Day
Methodology: Chemiluminescence
CPT: 82670
LOINC: 2243-4
Stability: Room Temperature: 20 Hrs; Refrigerated: 2 Days; Frozen: 6 Months
Reference Range:

FEMALE: Follicular Phase: 19.5 -144.2 pg/mL

Midcycle: 63.9 -356.7 pg/mL

Luteal Phase: 55.8 -214.2 pg/mL

Postmenopausal: ≤32.2 pg/mL

MALE: Adult: ≤39.8 pg/mL