Sign in →

Test Code FIBR Fibrinogen (Test Code – FIBR)

Specimen Type

Light Blue (Sodium Citrate – 3.2%) – Plasma Only

Specimen Handling Instructions

When using a butterfly draw a red top tube and discard, then proceed to draw a light blue top tube.

 

Collection Tube MUST be filled completely.  Gently invert the tube 3 to 4 times immediately after collection to ensure proper mixing of blood and anticoagulant.

Deliver to the lab as soon as possible.

If unable to deliver to the laboratory within the listed room temperature stability timeframe:

Centrifuge the light blue top tube and transfer plasma to an appropriately labeled plastic vial

Label vial PLASMA and Freeze immediately

 

Facility

Room Temperature

Whole Blood Stability

Frozen (-20C)

Plasma Stability

Canton-Potsdam Hospital

24 Hours

4 Months

Clifton Springs Hospital

8 Hours

2 Weeks

Newark Wayne Community Hospital

4 Hours

2 Weeks

Rochester General Hospital

4 Hours

2 Weeks

United Memorial Medical Center

4 Hours

2 Weeks

Unity Hospital

4 Hours

2 Weeks

Specimen Volume

3.0 mL Collection Tube MUST be filled completely. 

Stat Turn-around Time (from receipt in lab)

1 hour from specimen arrival in the laboratory

Routine Turn-around Time (from receipt in lab)

4 hours from specimen arrival in the laboratory

Reference Ranges

173 – 454 mg/dL

Methodology

Photo-optical clot detection

CPT Code

85384

LOINC Code:

3255-7