Sign in →

Test Code HGBA1C UMMC Hemoglobin A1C, Whole Blood

Specimen Collection Requirements

Hemoglobin A1c

Alternate Test Name: HbA1c, HgbA1c, Glycosylated Hemoglobin
Dept: Chemistry
SPECIMEN COLLECTION REQUIREMENTS
Collection Container:

Lavender (EDTA)

 

Specimen: Whole Blood
Transport Temperature: Room Temperature
Specimen Volume: Preferred Volume: 3 mL; Minimum Volume: 0.5 mL
TECHNICAL SPECIFICATIONS
Performed:  
Reported: Same Day
Methodology: Turbidimetric
CPT: 83036
LOINC: 4548-4
Stability: Room Temperature: 2 Days; Refrigerated: 7 Days; Frozen: 2 Months
Reference Range:

4.2 - 5.6 %

Notes: Per ADA 2018 Guidelines, HbA1c values should be interpreted as follows:
Normal: less than 5.7%
Prediabetes: 5.7%- 6.4%
Diabetes: 6.5% or higher
Samples containing high amounts of HbF (>7%) may yield lower than expected HbA1C results. Additional testing that is not affected by HbF can be considered and requested if clinically indicated. Please contact 585.922.LABS for more information.
Panel Components:
  • ESTIMATED AVERAGE GLUCOSE
  • HEMOGLOBIN A1C