Test Code PBDV Lead, Blood, Venous
Specimen Collection Requirements
Name: | Blood Lead, Venous |
Alt name: | Blood Lead, Lead |
Dept: | Elmgrove Chemistry |
Specimen: | Whole Blood |
Collection Cont.: | Tan Top certified Lead Free tube (preferred) |
Also acceptable: | Lavender EDTA tube |
Transport temp: | Refrigerated Temperature |
Stability: | Refrigerated up to 10 days |
Specimen Volume: | 1.0 mL (minimum 0.5 mL) |
TECHNICAL SPECIFICATIONS
Performed: | Business Days |
Reported: | Next Business Day |
Methodology: | Inductively Coupled Plasma Mass Spectrometry (ICPMS) |
Ref range: | Normal: ≤3.4 ug/dL |
Critcal value: | Critical: ≥45.0 ug/dL |
Linearity range: | <1.0 to >60.0 ug/dL |
CPT: | 83655 |
LOINC: | 77307-7 |
Notes
If the Blood Lead specimen is collected in an EDTA Lavender tube type |
and is ≥ 3.5 ug/dL, a disclaimer comment is added that suggests a redraw with a |
Tan Top certified Lead Free tube to confirm the actual Blood Lead level. |
To minimize Lead Contamination: |
1. Keep the collection area clean and dust free. |
2. Clean the venipuncture site with alcohol, not iodine. |
3. Do not ream out or remove blood clots from collection tube. |
4. Do not insert any objects into the specimen tube or pour off the sample. |